The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.

Out of stock

SKU: 1 6FM200Z-X Category: Tag:

Description

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid
General Features
● Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
● Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
● UL-recognized component.
● Can be mounted in any orientation.
● Computer designed lead, calcium tin alloy
grid for high power density.
● Long service life, float or cyclic
applications.
● Maintenance-free operation.
● Low self discharge.
Dimensions and Weight
Length(mm / inch) 522 / 20.55
Width(mm / inch) 238 / 9.37
Height(mm / inch) 218 / 8.58
Total Height(mm / inch) 223 / 8.78
Approx. Weight(Kg / lbs) 65 / 143.3
Performance Characteristics
Nominal Voltage 12V
Number of cell 6
Design Life 10 years
Nominal Capacity 77oF(25oC)
10 hour rate (20.0A, 10.8V) 200Ah
5 hour rate (36.7A, 10.5V) 183.5Ah
1 hour rate (138A, 9.6V) 138Ah
Internal Resistance
Fully Charged battery 77oF(25oC) 3mOhms
Self-Discharge
3% of capacity declined per month at 20oC(average)
Operating Temperature Range
Discharge -20~60oC
Charge -10~60oC
Storage -20~60oC
Max. Discharge Current 77oF(25oC) 1000A(5s)
Short Circuit Current 3500A
Charge Methods: Constant Voltage Charge 77oF(25oC)
Cycle use 14.4-14.7V
Maximum charging current 60A
Temperature compensation -30mV/oC
Standby use 13.6-13.8V
Temperature compensation -20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)
End Point
Volts/Cell 10min 15min 30min 1h 3h 5h 10h 20h
1.60V 440 358 210 138 53.1 39.0 20.5 10.70
1.65V 414 337 203 135 52.0 38.2 20.4 10.65
1.70V 390 316 195 132 51.0 37.5 20.3 10.60
1.75V 364 295 188 129 49.8 36.7 20.2 10.55
1.80V 334 274 180 126 48.4 35.9 20.0 10.5
Discharge Constant Power (Watts at 77oF25oC)
End Point
Volts/Cell 10min 15min 30min 45min 1h 2h 3h 5h
1.60V 756 611 402 287 266 145 103 74.3
1.65V 719 591 387 282 261 142 102 73.7
1.70V 681 572 372 276 256 139 100 73.1
1.75V 641 553 357 270 250 136 98.8 72.6
1.80V 609 520 342 265 245 132 97.7 72.0
page1 of 2 www.vision-batt.com
(Note)The above characteristics data are average values obtained within

Additional information

Weight 65 kg
Dimensions 50 × 40 × 30 cm